Thompson Energy Compliance Book a call
Thompson Energy Compliance

Thermal bridging

Getting the junctions right, to optimise your SAP or SBEM result.

Free 15-minute call, no obligation.

What it is

A thermal bridge is a place where heat escapes more easily than through the surrounding structure, usually at junctions such as where walls meet floors and roofs, or around windows and doors. Each junction has a psi-value that shows how much heat it loses.

In SAP and SBEM, poor or unknown junction values can add a large penalty to the result. Using standard details, or modelling the key junctions properly, often makes the difference between passing comfortably and needing expensive upgrades elsewhere. Good junction design also lowers the risk of condensation and mould.

When you need it

  • SAP and SBEM, where junction values feed into the result
  • New builds aiming for the Future Homes Standard, where every bit of performance counts
  • Timber and steel frame buildings, where standard details often don't apply
  • Designs with unusual junctions or details

How I help

  1. Standard details.

    Recognised construction details are included in every SAP package as standard.

  2. Spot the junctions that matter.

    I identify the few junctions that have the biggest effect on the result.

  3. Bespoke modelling.

    Where it makes a real difference, I model those junctions individually to calculate their actual psi-values.

  4. Feed it back into the design.

    You get clear advice on details that would improve performance.

What I'll need from you

  • Construction details or sections for the key junctions
  • Material specifications and thicknesses
  • The structural system, such as masonry, timber frame or steel frame

What you'll get

  • Junction psi-values used in the SAP or SBEM calculation
  • Calculation reports for any bespoke junctions
  • Notes on condensation risk at modelled junctions

FAQs

How long does thermal bridging take?
Standard details are part of the SAP, so they add no extra time. Bespoke modelling depends on the number of junctions, and I'll confirm timings when I quote.
How much does it cost?
Standard details are included in the SAP package. Bespoke modelling is priced by the number of junctions, and timber and steel frame buildings get a bespoke package to suit SAP calculations →.
Do I need bespoke thermal bridging?
Not always. Standard details are enough for many projects. Bespoke modelling is worth it where a few junctions are holding the result back, or where standard details don't fit the construction.
Why does it matter so much?
As walls, floors and roofs get better insulated, the junctions become a bigger share of the total heat loss. Under the Future Homes Standard, that share grows further.
Can thermal bridging help a design pass without changing it?
Often, yes. Modelling the real junctions can recover performance that the default penalty takes away, without changing the fabric or heating.
Is it only for new homes?
No. It applies to commercial buildings in SBEM too SBEM calculations →.

Areas covered

Based in Southampton, I cover Eastleigh, Winchester, Romsey, Hedge End, Fareham, Portsmouth, Andover, the New Forest and across Hampshire. Desk-based work such as SAP and SBEM can be done for projects nationwide.

Have a project in mind?

Share the drawings or just ask a question. Whatever stage you're at, it's a good time to talk.

CallWhatsApp